title: "HD30829 100–500 MHz RF Amplifier System"
description: "HD30829 RF amplifier system: 100–500 MHz. View specifications, download the matching datasheet and request a quote."
url: "https://rfamplifiers.com/hd30829/"
canonical: "https://rfamplifiers.com/hd30829/"
post_type: "page"
author: "ramibello"
date_published: "2026-10-01T20:21:51+00:00"
date_modified: "2026-11-09T02:11:35+00:00"
last-updated: "2026-11-09T02:11:35+00:00"
extractor: "elementor"
---

LOW FREQUENCY AMPLIFIER SYSTEM

# HD30829 RF Amplifier System

100–500 MHz · 1000 W minimum Psat output · 60 dB minimum gain

![HD30829 RF amplifier system product photo](https://rfamplifiers.com/wp-content/uploads/2026/10/hd30829-product.png)

SYSTEM

## HD30829

HD30829 is an RF amplifier system covering 100–500 MHz, listed in the Low Frequency Amplifier System product group. Compare the output-power rating, gain and supply requirements below with your application, then use the matching datasheet for detailed operating conditions.

|  |  |
| --- | --- |
| FREQUENCY RANGE100–500 MHz | OUTPUT POWER1000 W minimum Psat |
| GAIN60 dB minimum | SUPPLY VOLTAGE180 – 240 VAC |
| CONFIGURATIONSystem | CATEGORYLow Frequency Amplifier System |

************************

[Request a quote](#rfq)

[Download HD30829 datasheet](https://rfamplifiers.com/wp-content/uploads/2026/10/HD30829-0.1-1GHz-1000W-60dB-V1.2.pdf)

Values marked “catalog” follow the product matrix. Use the datasheet to confirm rating definitions and operating conditions.

DETAILED SPECIFICATION GROUPS

## HD30829 electrical specifications

Source: HD30829 (0.1 – 1GHz, 1000W, 60dB) V1.2.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.

| Parameter | Specification | Conditions / notes |
| --- | --- | --- |
| Operating Frequency Range | 100 – 500 MHz |  |
| Power Output @ Psat (CW) | 1000 W minimum | <0 dBm for rated Pout |
| Power Gain | 60 dB minimum |  |
| Power Gain Flatness | 3.0 dB p-p maximum | Constant input power |
| Gain Adjustment Range | 20 dB minimum | Local or remote capable |
| Input / Output Return Loss | -10 dB maximum |  |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 50 dBm/Tone, A = 1 MHz |
| Harmonics | -15 dBc typical | At rated output |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 180 – 240 VAC | 50 – 60 Hz |
| Power Consumption | 5 kW maximum | At rated output |

CONTROL & MONITORING

## HD30829 control and monitoring

| Parameter | Specification | Conditions / notes |
| --- | --- | --- |
| RF Connectors In/Out | Type-N / DIN Female | Front or rear panel |
| \\/O Connector | 9-Pin D-Sub |  |

Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.

ENVIRONMENTAL RATINGS

## Operating and storage conditions

| Parameter | Specification | Conditions / notes |
| --- | --- | --- |
| Operating Ambient Temperature | 0 to +50 °C |  |
| Storage Temperature | -40 to +85 °C |  |
| Relative Humidity | 5to 95% | Non Condensing |

PRODUCT SPECIFICATIONS

## Mechanical specifications and cooling

| Parameter | Specification | Conditions / notes |
| --- | --- | --- |
| Dimensions W x H x D | 421 × 308 × 600 mm | 7U, excluding handles |
| RF Connectors In/Out | Type-N / DIN Female | Front or rear panel |
| AC Power | MS Type | Or equivalent |
| \\/O Connector | 9-Pin D-Sub |  |
| Cooling | Built-in fan cooling | Variable speed |

Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.

TECHNICAL RESOURCES

## HD30829 documentation

Download **HD30829 (0.1 – 1GHz, 1000W, 60dB) V1.2.pdf** for the complete specifications, test conditions, drawings and available options.

[Download HD30829 datasheet](https://rfamplifiers.com/wp-content/uploads/2026/10/HD30829-0.1-1GHz-1000W-60dB-V1.2.pdf)

PRODUCT-SPECIFIC FAQS

## About HD30829

### What frequency range does HD30829 cover?

HD30829 is listed for 100–500 MHz operation.

### What output power and gain are specified?

Output: 1000 W minimum Psat. Gain: 60 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.

### What power supply and cooling does HD30829 require?

Supply: 180 - 240 VAC. Cooling: Built-in fan cooling.

### Which control and monitoring interfaces are available?

Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.

### What are the mechanical specifications?

Dimensions: 421 × 308 × 600 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.

### What do the protection ratings cover?

Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.

### Where can I get the HD30829 datasheet?

[Download the matching HD30829 datasheet](https://rfamplifiers.com/wp-content/uploads/2026/10/HD30829-0.1-1GHz-1000W-60dB-V1.2.pdf).

REQUEST A QUOTE

## Request a quote for HD30829

Send your requirements for pricing, availability and an engineering review. The model and category are prefilled below.

Prefer to contact us directly?
[sales@hdcom.com](mailto:sales@hdcom.com?subject=HD30829%20inquiry)
[+1 (631) 588-3877](tel:+16315883877)

## HD30829 Technical RFQ

### Product Details

- **Model / part number** (text)
- **Configuration / category** (text)
- **Quantity** (number)

### Contact Details

- **Full name** (text, required)
- **Work email** (email, required)
- **Company** (text, required)
- **Phone number (with country code)** (tel, required)

### Technical Requirements

- **Operating frequency range** (text)
- **Required output power** (text)
- **Technical requirements / documents requested** (textarea, required)

**Send HD30829 inquiry**