HD32081 RF Amplifier
System
HD32081
| FREQUENCY RANGE20–30,000 MHz | OUTPUT POWER100 W minimum Psat |
| GAIN50 dB minimum | SUPPLY VOLTAGE100 – 240 VAC |
| CONFIGURATIONSystem | CATEGORYUltra High Frequency amplifier System |
HD32081 electrical specifications
Source: HD32081 V2.2.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Band | A | B | |
| Operating Frequency Band | 20 – 1000 MHz | 1000 – 3000 MHz | |
| Band Switching Speed | 15 mS Nom | Coaxial relay – Local or Remote |
| Power Output @ Psat | 100 W minimum | |
| Power Gain | 50 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 4.0 dB p-p maximum | Constant input power |
| Input Return Loss | -10 dB maximum | |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 40 dBm/Tone, A = 1 MHz |
| Harmonics | -15 dB typical | At rated Pout |
| Non-Harmonics Spurious | -60 dBc maximum | |
| Operating Voltage | 100 – 240 VAC | |
| Power Consumption | 800 W maximum | At rated Pout |
HD32081 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| RF Connectors In/Out A / Out B | Type-N Female | Front or rear panel |
| Interface Connector | 9-Pin D-Sub | Rear panel |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Ambient Temperature | 0 to +50 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95 % | Non Condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions W x H x D | 430 × 133 × 560 mm | 3U – Excluding handles |
| RF Connectors In/Out A / Out B | Type-N Female | Front or rear panel |
| Interface Connector | 9-Pin D-Sub | Rear panel |
| AC Power | IEC 60320-C14 | Or equivalent |
| Cooling | Built-in fan cooling | Variable speed |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD32081 documentation
Download HD32081 V2.2.pdf for the complete specifications, test conditions, drawings and available options.
About HD32081
HD32081 is listed for 20–30,000 MHz operation.
Output: 100 W minimum Psat. Gain: 50 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 100 – 240 VAC. Cooling: Built-in fan cooling.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Dimensions: 430 × 133 × 560 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.