RF AMPLIFIERS · ENGINEERING SUPPORT

RF amplifier resources

Model-specific datasheets, practical specification guides and the information you need for a focused engineering inquiry.

HD31217

HD31217 V2.2.pdf

Electrical, mechanical and environmental information for this exact model. Review all footnotes and ordered options.

HD31759

HD31759 V3.1.pdf

Electrical, mechanical and environmental information for this exact model. Review all footnotes and ordered options.

HD30405

HD30405 (2 – 6GHz, 10W, 42dB) V4.1.pdf

Electrical, mechanical and environmental information for this exact model. Review all footnotes and ordered options.

HD33742

HD33742 V2.6.pdf

Electrical, mechanical and environmental information for this exact model. Review all footnotes and ordered options.

HD31266

HD31266 V0.4.pdf

Electrical, mechanical and environmental information for this exact model. Review all footnotes and ordered options.

HD31170

HD31170 (20 – 1000MHz, 20W, 43dB) V1.3.pdf

Electrical, mechanical and environmental information for this exact model. Review all footnotes and ordered options.

Looking for another model?

Browse the full product catalog or send the exact part number below. If a datasheet is unavailable, request the correct model document instead of substituting a similar amplifier.
READING SPECIFICATIONS

Understand the output-power rating

Psat: saturated output power describes operation in saturation. It does not establish distortion-free output for a modulated signal.

P1dB: the output level at which gain is compressed by 1 dB relative to the small-signal gain. Check whether the quoted value is minimum or typical and note the test conditions.

CW versus pulse: continuous-wave and pulsed ratings apply to different operating conditions. For pulses, review peak power, pulse width, repetition rate and duty cycle together.

Example: HD31217 V2.2 lists 25 W minimum CW at Psat and 12 W minimum CW at P1 dB. These are different operating points, not interchangeable ratings.

Gain & signal quality

Gain is the ratio of output power to input power, expressed in dB. Gain flatness describes variation across the specified frequency range under the stated test conditions.

For signal quality, review IMD, harmonics and spurious output separately. Preserve tone level, tone spacing and output-power conditions when comparing data.

Minimum, typical & maximum

Keep the datasheet’s labels with every value. A typical result is not a guaranteed minimum or maximum.

Check temperature, supply voltage, impedance and frequency conditions. A value stated at one test condition should not be assumed to apply across every operating condition.

INTEGRATION CHECKLIST

Review the complete installation requirements

  • Power: supply range, current consumption and power-up or shutdown requirements.
  • Cooling: heatsink, airflow and operating case-temperature limits.
  • RF connections: connector type, cable loss, impedance and load mismatch.
  • Control interface: pin assignments, logic levels and optional monitoring signals.
  • Mechanical fit: enclosure dimensions, mounting-hole positions and connector clearances.
  • Protection: input limits, VSWR conditions and any time limits. Protection is not permission for unlimited overload operation.
  • Environment: standard ratings versus optional environmental qualifications.
REQUEST-READY INFORMATION

Make your next inquiry more useful

Include the model number or operating frequency range, System/Module preference, output power and rating definition, signal type, pulse details where relevant, supply and cooling constraints, interface requirements, quantity and target schedule.

For a document request, specify whether you need the datasheet, mechanical drawing, interface pinout or clarification of a particular specification. Availability is confirmed by the sales team.

COMMON QUESTIONS

Answers for your next design decision

Use the document for the exact part number and confirm the applicable revision and ordered options. A similarly named model can have different ratings or interfaces.

Send the exact model number through the form below. Do not use a neighboring model’s data as a replacement.

Document contents vary. Use drawings and measured curves only when they are supplied for the exact model; request additional information when it is absent.

Yes. Share your installation, power, cooling, interface and signal requirements so the available configurations can be reviewed.

REQUEST A QUOTE

Let’s discuss your technical requirements

Tell us your frequency range, output-power requirements and operating conditions. Include a model number if you have one.
Prefer to contact us directly?
sales@hdcom.com
+1 (631) 588-3877

We will use the details you provide to respond to your inquiry. Privacy Policy