BROADBAND AMPLIFIER SYSTEM

HD33742 RF Amplifier
System

1,000–6,000 MHz · 300 W minimum, CW or pulse Psat · 55 dB minimum gain
HD33742 RF amplifier product photo
SYSTEM

HD33742

HD33742 is a system covering 1,000–6,000 MHz. Its model-specific datasheet specifies 300 W minimum, CW or pulse saturated output and 55 dB minimum gain.
FREQUENCY RANGE1,000–6,000 MHzSATURATED OUTPUT (PSAT)300 W minimum, CW or pulse
POWER GAIN55 dB minimumSUPPLY VOLTAGE200–240 VAC, 50–60 Hz
CONFIGURATIONSystemCATEGORYBroadband Amplifier System
P1dB: 180 W minimum. Refer to the datasheet for complete limits, test conditions and integration requirements.
ELECTRICAL SPECIFICATIONS

HD33742 electrical specifications

From the matching HD33742 V2.6 datasheet. Test conditions: 25 °C, 50 Ω. Minimum, maximum and typical ratings retain the datasheet qualifiers.

ParameterSpecificationConditions / notes
Operating frequency1.0–6.0 GHz—
Saturated output (Psat)300 W minimumCW or pulse
Output at P1 dB180 W minimum—
Power gain55 dB minimum0 dBm or less for rated output
Gain flatness4 dB p-p maximumConstant input power
Gain adjustment range20 dB minimumLocal or remote
Input return loss−10 dB maximum—
Two-tone IMD−30 dBc typical43 dBm/tone; Δ = 1 MHz
Harmonics−20 dBc typicalAt rated output
Spurious−60 dBc maximumNon-harmonic
Operating voltage200–240 VAC50–60 Hz
Power consumption3.5 kW maximum / 3 kW typicalAt rated output
Input power protection+8 dBm maximumWith optional digital monitor and control; basic units: less than 10 seconds without damage
Load VSWR protection4:1 maximumFoldback at preset limit with optional digital monitor and control; basic units: less than 1 minute at rated output
Sample port−50 dBOptional; N-female
CONTROL AND MONITORING

HD33742 control and monitoring

Optional interfaces and monitoring functions from the matching model datasheet.

FunctionSpecificationConditions / notes
Digital monitor and control (DMC)OptionalFWD, REV, VSWR, gain, ALC, voltage, current and temperature
Remote interfacesEthernet RJ-45 TCP/IP, RS422/485, USBWith optional DMC
GPIB remote controlOptionalIEEE-488
Safety interlock (INT)OptionalOpen = standby; short = RF on; BNC female on rear panel
Forward RF sample (FRS)Optional; −50 dBSMA or N-female; front or rear panel
Reflected RF sample (RRS)Optional; −50 dBSMA or N-female; front or rear panel
Calibrated power monitoring (CPM)Included with DMC purchaseOffset correction entry for ±0.2 dB accuracy; 11 points standard; consult factory for additional points
ENVIRONMENTAL RATINGS

HD33742 operating and storage conditions

Environmental limits from the matching model datasheet.

ParameterSpecificationConditions / notes
Operating ambient temperature0 to +50 °C—
Storage temperature−40 to +85 °C—
Relative humidityUp to 95%Non-condensing
Altitude3,000 m—
Shock and vibrationNormal transportMIL specification available for quotation
PRODUCT SPECIFICATIONS

HD33742 mechanical specifications and cooling

Use the model-specific outline drawing in the PDF when planning mounting and connector clearance.

ParameterSpecificationConditions / notes
Dimensions (W × H × D)421 × 220 × 750 mm5U; excluding handles
Weight53 kg maximum—
RF input / output / optional sampleType N femaleFront or rear panel
AC power / interfaceIEC 60320-C14 / 9-pin D-SubOr equivalent
Built-in Quiet-Cool coolingClosed-circuit air-liquid cooling—
TECHNICAL RESOURCES

HD33742 documentation

The linked file is HD33742 V2.6.pdf, matched to HD33742. It contains electrical, environmental and mechanical specifications, control options and outline drawings. Check the drawings for the selected options; specifications and drawings may vary with options.

PRODUCT-SPECIFIC FAQS

About HD33742

The HD33742 datasheet lists 1.0–6.0 GHz.

Saturated output (Psat): 300 W minimum; CW or pulse. Output at P1dB: 180 W minimum.

200–240 VAC; 50–60 Hz. Power consumption: 3.5 kW maximum / 3 kW typical; at rated output.

Optional DMC supports forward/reflected power, VSWR, gain, ALC, voltage, current and temperature monitoring. The datasheet lists Ethernet TCP/IP, RS422/485 and USB, with optional GPIB. Optional interlock: open = standby; short = RF on.

Closed-circuit air-liquid cooling. Operating ambient temperature: 0 to +50 °C. Storage temperature: −40 to +85 °C.

Input power protection: +8 dBm maximum; with optional digital monitor and control; basic units: less than 10 seconds without damage. Load VSWR protection: 4:1 maximum; foldback at preset limit with optional digital monitor and control; basic units: less than 1 minute at rated output.

Open HD33742 V2.6.pdf for the complete ratings, pin assignments or control options, and outline drawings.

REQUEST A QUOTE

Request a quote for HD33742

Send your requirements for pricing, availability and an engineering review. The model and category are prefilled below.
Prefer to contact us directly?
sales@hdcom.com
+1 (631) 588-3877

We will use the details you provide to respond to your inquiry. Privacy Policy