HD35212 RF Amplifier
Module
HD35212
| FREQUENCY RANGE2,700–3,100 MHz | OUTPUT POWER500 W (catalog) |
| GAIN57 dB minimum | SUPPLY VOLTAGE50 VDC Nom |
| CONFIGURATIONModule | CATEGORYLow Frequency Module |
HD35212 electrical specifications
Source: HD35212 V1.4.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 2.7 – 3.1 GHz | |
| Power Output @ Pulse | 500 W minimum | Peak Pulse |
| Power Gain | 57 dB minimum | |
| Input Return Loss | -12 dB maximum | Relative to 50 Ohm |
| Harmonics | -30 dBc maximum | At rated Pout |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 50 VDC Nom |
HD35212 control and monitoring
| Pin | Function | Description |
|---|---|---|
| P2 | GND | Ground |
| Al | VDD | +50 VDC |
| A2 | GND | Ground |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +70°C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | 5to95% | Non-condensing |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 180 × 120 × 32 mm | Excluding connectors |
| RF Connectors In/Out | SMA Female / Type N Female | |
| DC Power / Interface Connector | 7-Pin Hybrid D-Sub | 7W2 |
| Cooling | External heatsink | Forced air required |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD35212 documentation
Download HD35212 V1.4.pdf for the complete specifications, test conditions, drawings and available options.
About HD35212
HD35212 is listed for 2,700–3,100 MHz operation.
Output: 500 W (catalog). Gain: 57 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 50 VDC Nom. Cooling: External heatsink.
See the model-specific interface table above. Optional functions must be confirmed for the ordered unit.
Dimensions: 180 × 120 × 32 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.