HD31530 RF Amplifier
Module
HD31530
| FREQUENCY RANGE26,000–32,000 MHz | OUTPUT POWER10 W (catalog) |
| GAIN40 dB minimum | SUPPLY VOLTAGE9.0 VDC Nom |
| CONFIGURATIONModule | CATEGORYMillimeter Amplifier Module |
HD31530 electrical specifications
Source: HD31530 V2.1.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
Frequency clarification: This page follows the matching PDF (26,000–32,000 MHz). The product matrix lists 26,000–31,000 MHz. Confirm the required frequency range when requesting a quote.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 26.0 – 32.0 GHz | |
| Power Output | 10 W minimum | CW |
| Power Output @ P1 dB GCP | 8 W typical | |
| Power Gain | 40 dB minimum | |
| Power Gain Flatness | 4.0 dB p-p maximum | Constant input power |
| Input / Output Return Loss | 10 dB minimum | Relative to 50 Ohm |
| Harmonics | <-20 dBc typical | At rated Pout |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 9.0 VDC Nom | |
| Current Consumption | 19 A maximum | At rated Pout |
HD31530 control and monitoring
| Pin | Function | Description |
|---|---|---|
| 1 | n/c | Reserved |
| 2 | n/c | Reserved |
| 5 | SHUTDOWN | TTL |
| A2 | GND | Ground |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +55 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | 5to95% | Non-condensing |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | NO x 130 × 22 mm | Excluding connectors |
| RF Connectors In/Out | 2.92 mm (kK) female | |
| DC Power / Interface Connector | 7-Pin Hybrid D-Sub | |
| Cooling | External heatsink | Forced air required |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD31530 documentation
Download HD31530 V2.1.pdf for the complete specifications, test conditions, drawings and available options.
About HD31530
HD31530 is listed for 26,000–32,000 MHz operation.
Output: 10 W (catalog). Gain: 40 dB minimum. P1dB: 8 W typical. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 9.0 VDC Nom. Cooling: External heatsink.
See the model-specific interface table above. Optional functions must be confirmed for the ordered unit.
Dimensions: NO x 130 × 22 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.