HD30364 RF Amplifier
Module
HD30364
| FREQUENCY RANGE500–2,500 MHz | OUTPUT POWER125 W minimum Psat |
| GAIN51 dB minimum | SUPPLY VOLTAGE32 VDC Nom |
| CONFIGURATIONModule | CATEGORYLow Frequency Module |
HD30364 electrical specifications
Source: HD30364 V1.2.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 500 – 2500 MHz | |
| Power Output @ Psat | 125 W minimum | CW |
| Power Gain | 51 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 3.0 dB p-p maximum | Constant input power |
| Input Return Loss | -10 dB maximum | Relative to 50 Ohm |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 39 dBm/Tone, A = 1 MHz |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 32 VDC Nom | |
| Current Consumption | 13 A maximum | At rated Pout |
| Turn On / Off Speed | 5 Sec maximum |
HD30364 control and monitoring
| Pin | Function | Description |
|---|---|---|
| 1 | n/c | n/c |
| 2 | N/c | N/c |
| 5 | SHUTDOWN | Enable = TTL High or Open; Disable = TTL Low or Short |
| 6,7 | VDD | 32 VDC |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +75 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95 % | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 188 × 91.4 × 27 mm | Excluding connectors |
| RF Connectors In/Out | SMA-female | |
| DC Power / Interface Connector | 9-Pin D-Sub | |
| Cooling | External heatsink | Forced air required |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD30364 documentation
Download HD30364 V1.2.pdf for the complete specifications, test conditions, drawings and available options.
About HD30364
HD30364 is listed for 500–2,500 MHz operation.
Output: 125 W minimum Psat. Gain: 51 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 32 VDC Nom. Cooling: External heatsink.
See the model-specific interface table above. Optional functions must be confirmed for the ordered unit.
Dimensions: 188 × 91.4 × 27 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.