HD33626 RF Amplifier
Module
HD33626
| FREQUENCY RANGE1,000–2,000 MHz | OUTPUT POWER1,000 W (catalog) |
| GAIN60 dB Nom | SUPPLY VOLTAGE50 VDC Nom |
| CONFIGURATIONModule | CATEGORYLow Frequency Module |
HD33626 electrical specifications
Source: HD33626 V3.2.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Switching Delay Time (Td) | 200 ns typical | |
| Power Gain | 60 dB Nom | |
| Power Gain Flatness | 2.0 dB p-p typical | |
| Input / Output Return Loss | -12 dB maximum | Relative to 50 Ohm |
| Spurious | -65 dBc maximum | |
| Operating Voltage | 50 VDC Nom | Non-harmonics |
HD33626 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| RF Connectors In/Out | SMA Female / Type-N Female | |
| DC Power / Interface Connector | 7-Pin Hybrid D-Sub | 7W2 |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | 95 % maximum | Non-condensing |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| RF Connectors In/Out | SMA Female / Type-N Female | |
| DC Power / Interface Connector | 7-Pin Hybrid D-Sub | 7W2 |
| Cooling | External heatsink | Forced air required |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD33626 documentation
Download HD33626 V3.2.pdf for the complete specifications, test conditions, drawings and available options.
About HD33626
HD33626 is listed for 1,000–2,000 MHz operation.
Output: 1,000 W (catalog). Gain: 60 dB Nom. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 50 VDC Nom. Cooling: External heatsink.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.