HD30406 RF Amplifier
Module
HD30406
| FREQUENCY RANGE6,000–18,000 MHz | OUTPUT POWER10 W minimum Psat |
| GAIN40 dB minimum | SUPPLY VOLTAGE12 VDC Nom |
| CONFIGURATIONModule | CATEGORYUltra High Frequency amplifier Module |
HD30406 electrical specifications
Source: HD30406 V1.5.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 6.0 – 18.0 GHz | |
| Power Output Psat | 10 W minimum | CW |
| Power Gain | 40 dB minimum | |
| Power Gain Flatness | 4.0 dB p-p maximum | |
| Input Return Loss | -10 dB maximum | 50 Ohm reference |
| Harmonics | -15 dBc typical | At rated Pout |
| Noise Figure | 10 dB maximum | |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 12 VDC Nom | |
| Current Consumption | 13 A maximum / <12 A typical | At rated Pout |
HD30406 control and monitoring
| Pin | Function | Description |
|---|---|---|
| 1 | N/A | N/A |
| 2 | N/A | N/A |
| 6,7 | VDD | 12 VDC |
| 8,9 | GND | Ground |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +65 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | 5to95% | Non-condensing |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 100 × 100 × 27 mm | Excluding connectors |
| RF Connectors In/Out | Hi Freq. SMA-female | |
| DC Power / Interface Connector | 9-Pin D-Sub | |
| Cooling | External heatsink | Forced air required |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD30406 documentation
Download HD30406 V1.5.pdf for the complete specifications, test conditions, drawings and available options.
About HD30406
HD30406 is listed for 6,000–18,000 MHz operation.
Output: 10 W minimum Psat. Gain: 40 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 12 VDC Nom. Cooling: External heatsink.
See the model-specific interface table above. Optional functions must be confirmed for the ordered unit.
Dimensions: 100 × 100 × 27 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.