HD30969 RF Amplifier
Module
HD30969
| FREQUENCY RANGE1–20 MHz | OUTPUT POWER400 W (catalog) |
| GAIN40 dB (catalog) | SUPPLY VOLTAGE50 VDC Nom |
| CONFIGURATIONModule | CATEGORYLow Frequency Module |
HD30969 electrical specifications
Source: HD30969 V2.1.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Power Output @ Pulse | 400 W minimum | Peak pulse |
| Power Gain @ Peak Pulse | 40 dB minimum | +16 dBm or less for rated Pout |
| Power Gain Flatness | 2.0 dB p-p maximum | |
| Input Return Loss | -10 dB maximum | |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 50 VDC Nom | |
| Turn On / Off Speed | 10 pSec maximum |
HD30969 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| RF Connectors In/Out | SMA female / Type-N female | |
| DC Power / Interface Connector | 9-Pin D-Sub |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +75 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95% | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 200 × 106 × 33 mm | Excluding connectors |
| RF Connectors In/Out | SMA female / Type-N female | |
| DC Power / Interface Connector | 9-Pin D-Sub | |
| Cooling | External heatsink | Forced air required |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD30969 documentation
Download HD30969 V2.1.pdf for the complete specifications, test conditions, drawings and available options.
About HD30969
HD30969 is listed for 1–20 MHz operation.
Output: 400 W (catalog). Gain: 40 dB (catalog). Preserve the rating definitions and conditions in the complete datasheet.
Supply: 50 VDC Nom. Cooling: External heatsink.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Dimensions: 200 × 106 × 33 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.