| FREQUENCY RANGE1,000–6,000 MHz | OUTPUT POWER10 W minimum / 20 W typical Psat |
| GAIN40 dB minimum | SUPPLY VOLTAGE28 – 30 VDC |
| CONFIGURATIONModule | CATEGORYBroadband Amplifier Module |
HD31273 electrical specifications
Source: HD31273 V1.5.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 1.0 – 6.0 GHz | |
| Power Output @ Psat | 10 W minimum / 20 W typical | CW |
| Output Power @ P1 dB | 6 W minimum / 10 W typical | CW |
| Power Gain | 40 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 3.0 dB p-p maximum | Constant input power |
| Input Return Loss | -10 dB minimum | Relative to 50 Ohm |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 30 dBm/Tone, A = 1 MHz |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 28 – 30 VDC | |
| Current Consumption | 3.4 A typical | At rated Pout |
HD31273 control and monitoring
| Pin | Function | Description |
|---|---|---|
| 1 | FWD | Option-101 |
| 2 | REV | Option-102 |
| 5 | SHUTDOWN | Enable = TTL High or Open; Disable = TTL Low or Short |
| 6,7 | VDD | 28 VDC |
| 8,9 | GND | Ground |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +75 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | 5to95% | Non-condensing |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 156.4 × 69 × 27 mm | Excluding connectors |
| RF Connectors In/Out | SMA female | |
| DC Power / Interface Connector | 9-Pin D-Sub | |
| Cooling | External heatsink | Forced air required |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD31273 documentation
Download HD31273 V1.5.pdf for the complete specifications, test conditions, drawings and available options.
About HD31273
HD31273 is listed for 1,000–6,000 MHz operation.
Output: 10 W minimum / 20 W typical Psat. Gain: 40 dB minimum. P1dB: 6 W minimum / 10 W typical. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 28 – 30 VDC. Cooling: External heatsink.
See the model-specific interface table above. Optional functions must be confirmed for the ordered unit.
Dimensions: 156.4 × 69 × 27 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.