HD31829 RF Amplifier
Module
HD31829
| FREQUENCY RANGE2,000–8,000 MHz | OUTPUT POWER50 W minimum Psat |
| GAIN47 dB minimum | SUPPLY VOLTAGE32 VDC Nom |
| CONFIGURATIONModule | CATEGORYBroadband Amplifier Module |
HD31829 electrical specifications
Source: HD31829 V0.6.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 2.0 – 8.0 GHz | |
| Power Output @ Psat | 50 W minimum | CW |
| Power Gain | 47 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 4.0 dB p-p maximum | Constant input power |
| Input / Output Return Loss | -10 dB maximum | |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 37 dBm/Tone, A = 1 MHz |
| Harmonics | -15 dBc typical | At rated Pout |
| Operating Voltage | 32 VDC Nom | |
| Current Consumption | 14 A maximum | At rated Pout / Psat |
HD31829 control and monitoring
| Pin | Function | Description |
|---|---|---|
| 1 | N/c | N/c |
| 2 | VA | N/c |
| 6,7 | VDD | 32 VDC |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +75 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95% | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 200 × 110 × 25 mm | Excluding connectors |
| RF Connectors In/Out | SMA female | |
| DC Power / Interface Connector | 9 Pin D-Sub |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD31829 documentation
Download HD31829 V0.6.pdf for the complete specifications, test conditions, drawings and available options.
About HD31829
HD31829 is listed for 2,000–8,000 MHz operation.
Output: 50 W minimum Psat. Gain: 47 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 32 VDC Nom. Confirm cooling and installation requirements in the datasheet.
See the model-specific interface table above. Optional functions must be confirmed for the ordered unit.
Dimensions: 200 × 110 × 25 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.