HD31942 RF Amplifier
Module
HD31942
| FREQUENCY RANGE26,500–40,000 MHz | OUTPUT POWER34 dBm minimum Psat |
| GAIN36 dB minimum | SUPPLY VOLTAGE8 VDC Nom |
| CONFIGURATIONModule | CATEGORYMillimeter Amplifier Module |
HD31942 electrical specifications
Source: HD31942 V1.2.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 26.5 – 40 GHz | |
| Power Output @ Psat | 34 dBm minimum | |
| Output Power @ P1 dB G.C.P. | 30 dBm minimum | |
| Linear Gain | 36 dB minimum | |
| Gain Flatness | +2.2 dB typical / +3.5 dB maximum | |
| Noise Figure | 6 dB typical | |
| Operating Voltage | 8 VDC Nom | |
| Current Consumption | <7 A typical / 7.5 AMP maximum |
HD31942 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Input / Output RF Connectors | 2.9 mm K-Female |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +60 °C | |
| Storage Temperature | -40 to +70 °C | Non-operating |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 77 × 73 × 20 mm | |
| Input / Output RF Connectors | 2.9 mm K-Female |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD31942 documentation
Download HD31942 V1.2.pdf for the complete specifications, test conditions, drawings and available options.
About HD31942
HD31942 is listed for 26,500–40,000 MHz operation.
Output: 34 dBm minimum Psat. Gain: 36 dB minimum. P1dB: 30 dBm minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 8 VDC Nom. Confirm cooling and installation requirements in the datasheet.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Dimensions: 77 × 73 × 20 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.