| FREQUENCY RANGE2,000–8,000 MHz | OUTPUT POWER70 W minimum Psat |
| GAIN48 dB minimum | SUPPLY VOLTAGE32 VDC Nom |
| CONFIGURATIONModule | CATEGORYBroadband Amplifier Module |
HD32007 electrical specifications
Source: HD32007 V1.3.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 2.0 – 8.0 GHz | |
| Power Output @ Psat | 70 W minimum | CW |
| Power Gain | 48 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 4.0 dB p-p maximum | Constant input power |
| Input / Output Return Loss | -10 dB maximum | |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 37 dBm/Tone, A = 1 MHz |
| Operating Voltage | 32 VDC Nom | |
| Current Consumption | 14 A typical | At rated Pout / Psat |
HD32007 control and monitoring
| Pin | Function | Description |
|---|---|---|
| 1 | FWD | n/c |
| 2 | VVA | n/c |
| 6,7 | VDD | 32 VDC |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +75 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95 % | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 250 × 110 × 25 mm | Excluding connectors |
| RF Connectors In/Out | SMA female | |
| DC Power / Interface Connector | 7 Pin Hybrid D-Sub | |
| Cooling | External heatsink | Forced air required |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD32007 documentation
Download HD32007 V1.3.pdf for the complete specifications, test conditions, drawings and available options.
About HD32007
HD32007 is listed for 2,000–8,000 MHz operation.
Output: 70 W minimum Psat. Gain: 48 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 32 VDC Nom. Cooling: External heatsink.
See the model-specific interface table above. Optional functions must be confirmed for the ordered unit.
Dimensions: 250 × 110 × 25 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.