HD32302 RF Amplifier
Module
HD32302
| FREQUENCY RANGE6,000–18,000 MHz | OUTPUT POWER40 W minimum Psat |
| GAIN46 dB minimum | SUPPLY VOLTAGE32 VDC Nom |
| CONFIGURATIONModule | CATEGORYUltra High Frequency amplifier Module |
HD32302 electrical specifications
Source: HD32302 V0.5.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 6.0 – 18.0 GHz | |
| Power Output Psat | 40 W minimum | CW |
| Power Gain | 46 dB minimum | |
| Power Gain Flatness | 4.0 dB p-p maximum | |
| Input / Output VSWR | 2:1Min | |
| Harmonics | -15 dBc typical | At rated Pout |
| Spurious | -60 dBc maximum | Non-harmonics |
| Noise Figure | 10 dB maximum | |
| Operating Voltage | 32 VDC Nom | |
| Efficiency | 10 % minimum | At rated Pout |
HD32302 control and monitoring
| Pin | Function | Description |
|---|---|---|
| 1 | GND | Ground |
| 2 | N/c | N/A |
| Al | VDD | 32 VDC |
| A2 | GND | Ground |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | 0 to +50 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | 5 to 95% | Non-condensing |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| RF Connectors In/Out | SMA female | Cover Flange |
| DC Power / Interface Connector | 7-Pin Hybrid D-Sub | |
| Cooling | External heatsink | Forced air required |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD32302 documentation
Download HD32302 V0.5.pdf for the complete specifications, test conditions, drawings and available options.
About HD32302
HD32302 is listed for 6,000–18,000 MHz operation.
Output: 40 W minimum Psat. Gain: 46 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 32 VDC Nom. Cooling: External heatsink.
See the model-specific interface table above. Optional functions must be confirmed for the ordered unit.
Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.