HD33384 RF Amplifier
System
HD33384
| FREQUENCY RANGE1,030–1,090 MHz | OUTPUT POWER2000 PULSE (catalog) |
| GAIN63 dB + 2.0 dB | SUPPLY VOLTAGE100 – 240 VAC |
| CONFIGURATIONSystem | CATEGORYPulse Amplifier System |
HD33384 electrical specifications
Source: HD33384 (1030 – 1090MHz, 2000W, 63 dB ± 2.0dB) V1.3.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 1030 & 1090 MHz | |
| Power Output @ Peak Pulse | 2000 W minimum | |
| Power Gain | 63 dB + 2.0 dB | Pin = 0 dBm for Nom Pout |
| Power Gain Flatness | 1.0 dB p-p maximum | Constant input power |
| Input Return Loss | -10 dB maximum | Relative to 50 Ohm |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 100 – 240 VAC | |
| Power Consumption | 6 kW Peak maximum / 400 W Avg maximum | 2000 W with DS = 4% |
HD33384 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Interface Connector | 9-Pin D-Sub | Rear panel |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95% | Non Condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| RF Conn. In / Out / Sample | N-Female | Front or rear panel |
| Interface Connector | 9-Pin D-Sub | Rear panel |
| AC Power | IEC 60320-C14 | Or equivalent |
| Cooling | Built-in fan cooling | Variable speed |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD33384 documentation
Download HD33384 (1030 – 1090MHz, 2000W, 63 dB ± 2.0dB) V1.3.pdf for the complete specifications, test conditions, drawings and available options.
About HD33384
HD33384 is listed for 1,030–1,090 MHz operation.
Output: 2000 PULSE (catalog). Gain: 63 dB + 2.0 dB. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 100 – 240 VAC. Cooling: Built-in fan cooling.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.