HD33576 RF Amplifier
System
HD33576
| FREQUENCY RANGE80–1,000 MHz | OUTPUT POWER750 W minimum Psat |
| GAIN60 dB minimum | SUPPLY VOLTAGE180 – 240 VAC |
| CONFIGURATIONSystem | CATEGORYLow Frequency Amplifier System |
HD33576 electrical specifications
Source: HD33576 (80 – 1000MHz, 750W, 60dB) V1.7.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 80 – 1000 MHz | CW or Pulse |
| Power Output @ Psat | 750 W minimum | IKW typical, 80 – SOOMHz |
| Power Output @ P1 dB | 500 W typical | |
| Power Gain | 60 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 3.0 dB p-p maximum | Constant input power |
| Gain Adjustment Range | 20 dB minimum | Local or remote capable |
| Input Return Loss | -10 dB maximum | |
| Noise Figure | 10 dB typical | At full gain |
| Harmonics | -20 dBc maximum | |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 180 – 240 VAC | 50 – 60Hz |
| Power Consumption | 5000 W maximum | At rated Pout |
HD33576 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| RF Connectors In/Out/Sample | N-Female / 716-Female / N-Female | Front or rear panel |
| Interface Connector | 9-Pin D-Sub | Rear panel |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Ambient Temperature | 0 to +50 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95 % | Non Condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions W x H x D | 421 × 220 × 750 mm | 5U, excluding handles |
| RF Connectors In/Out/Sample | N-Female / 716-Female / N-Female | Front or rear panel |
| Interface Connector | 9-Pin D-Sub | Rear panel |
| AC Power | IEC 60320-C14 | Or equivalent |
| Cooling: Built in Quiet-Cool | Closed-circuit air-liquid cooling |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD33576 documentation
Download HD33576 (80 – 1000MHz, 750W, 60dB) V1.7.pdf for the complete specifications, test conditions, drawings and available options.
About HD33576
HD33576 is listed for 80–1,000 MHz operation.
Output: 750 W minimum Psat. Gain: 60 dB minimum. P1dB: 500 W typical. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 180 – 240 VAC. Cooling: Closed-circuit air-liquid cooling.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Dimensions: 421 × 220 × 750 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.