| FREQUENCY RANGE6,000–18,000 MHz | OUTPUT POWER100 W minimum* Psat |
| GAIN50 dB minimum | SUPPLY VOLTAGE100 – 240 VAC |
| CONFIGURATIONSystem | CATEGORYUltra High Frequency amplifier System |
HD33987 electrical specifications
Source: HD33987 (6 – 18GHz, 100W, 50dB) V1.8.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 6.0 – 18.0 GHz | |
| Power Output @ Psat | 100 W minimum* | CW or Pulse |
| Power Gain | 50 dB minimum | 0 dBm or less for rated Pout |
| Gain Adjustment Range | 20 dB minimum | Local or remote capable |
| Power Gain Flatness | 4 dB p-p maximum | Constant input power |
| Input / Output Return Loss | -10 dB maximum | |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 40 dBm/Tone, A = 1 MHz |
| Harmonics | -20 dBc typical | At rated output |
| Operating Voltage | 100 – 240 VAC | 50 – 60Hz |
| Power Consumption | 1500 W maximum | At rated output |
HD33987 control and monitoring
Use the matching datasheet to confirm available control and monitoring interfaces for the ordered configuration.
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Ambient Temperature | 0 to +50°C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95 % | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
Confirm enclosure dimensions, RF connectors, mounting and cooling requirements in the matching datasheet.
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD33987 documentation
Download HD33987 (6 – 18GHz, 100W, 50dB) V1.8.pdf for the complete specifications, test conditions, drawings and available options.
About HD33987
HD33987 is listed for 6,000–18,000 MHz operation.
Output: 100 W minimum* Psat. Gain: 50 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 100 – 240 VAC. Confirm cooling and installation requirements in the datasheet.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.