HD34066 RF Amplifier
System
HD34066
| FREQUENCY RANGE8,000–12,000 MHz | OUTPUT POWER4 kW Pulse (catalog) |
| GAIN66 dB minimum | SUPPLY VOLTAGE120/208 VAC, 3-Ph, 47 – 63 Hz |
| CONFIGURATIONSystem | CATEGORYPulse Amplifier System |
HD34066 electrical specifications
Source: HD34066 (8 – 12GHz, 4kW Pulse, 66dB) V0.4.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Band | A | A | Band switching @ 15 mS typical |
| Operating Frequency Range | 8 – 10 GHz | 10 – 12 GHz | |
| Pulse Power Output | 4.0 kW typical | Peak Pulse |
| Power Gain | 66 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 5.0 dB p-p maximum | Constant input power |
| Gain Adjustment Range | 20 dB minimum | Local or remote capable |
| Input Return Loss | -10 dB maximum | |
| Output Power On/Off Ratio | 80 dB maximum | TTL Gate Control |
| Harmonics | -20 dBc typical | At rated output power |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 120/208 VAC, 3-Ph, 47 – 63 Hz | Opt: 230/400 VAC, 3-Ph |
| Power Consumption | 5000 W Avg maximum | At rated Pout |
HD34066 control and monitoring
Use the matching datasheet to confirm available control and monitoring interfaces for the ordered configuration.
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95 % | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
Confirm enclosure dimensions, RF connectors, mounting and cooling requirements in the matching datasheet.
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD34066 documentation
Download HD34066 (8 – 12GHz, 4kW Pulse, 66dB) V0.4.pdf for the complete specifications, test conditions, drawings and available options.
About HD34066
HD34066 is listed for 8,000–12,000 MHz operation.
Output: 4 kW Pulse (catalog). Gain: 66 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 120/208 VAC, 3-Ph, 47 – 63 Hz. Confirm cooling and installation requirements in the datasheet.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.