HD34796 RF Amplifier
System
HD34796
| FREQUENCY RANGE100–1,000 MHz | OUTPUT POWER200 W minimum Psat |
| GAIN53 dB minimum | SUPPLY VOLTAGE100 – 240 VAC |
| CONFIGURATIONSystem | CATEGORYLow Frequency Amplifier System |
HD34796 electrical specifications
Source: HD34796 (0.1 – 1GHz, 200W, 53dB) V0.2.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 100 – 1000 MHz | |
| Power Output @ Psat | 200 W minimum | CW or Pulse |
| Power Output @ P1 dB GCP | 150 W typical | |
| Power Gain | 53 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 3.0 dB p-p maximum | Constant input power |
| Gain Adjustment Range | >20 dB typical | Local or remote capable |
| Input Return Loss | -10 dB maximum | |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 43 dBm/Tone, A = 1 MHz |
| Harmonics | -20 dBc typical | At rated output power |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 100 – 240 VAC | 50/60 Hz |
| Power Consumption | 1200 W maximum | At rated output |
HD34796 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| RF Connectors In/Out/Sample | Type-N Female | Front or rear panel |
| AC Power / Interface Connector | IEC 60320-C14 / 9-Pin D-Sub |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Ambient Temperature | 0 to +50°C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95 % | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions W x H x D | 421 × 131 × 650 mm | 3U – excluding connectors |
| RF Connectors In/Out/Sample | Type-N Female | Front or rear panel |
| AC Power / Interface Connector | IEC 60320-C14 / 9-Pin D-Sub | |
| Cooling: Built in Quiet-Cool | Closed-circuit air-liquid cooling | 60-65 dBa typical |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD34796 documentation
Download HD34796 (0.1 – 1GHz, 200W, 53dB) V0.2.pdf for the complete specifications, test conditions, drawings and available options.
About HD34796
HD34796 is listed for 100–1,000 MHz operation.
Output: 200 W minimum Psat. Gain: 53 dB minimum. P1dB: 150 W typical. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 100 – 240 VAC. Cooling: Closed-circuit air-liquid cooling.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Dimensions: 421 × 131 × 650 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.