HD35099 RF Amplifier
Module
HD35099
| FREQUENCY RANGE1,000–6,000 MHz | OUTPUT POWER3 W minimum Psat |
| GAIN35 dB minimum | SUPPLY VOLTAGE28 – 30 VDC |
| CONFIGURATIONModule | CATEGORYBroadband Amplifier Module |
HD35099 electrical specifications
Source: HD35099 V1.2.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 1000 – 6000 MHz | |
| Power Output @ Psat | 3 W minimum | CW |
| Power Output @ P1 dB | 2 W typical | CW |
| Power Gain | 35 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 3.0 dB p-p maximum | Constant input power |
| Input Return Loss | -10 dB maximum | Relative to 50 Ohm |
| 2-Tone Intermodulation (IMD) | <-30 dBc typical | 25 dBm/Tone, A = 1 MHz |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 28 – 30 VDC | |
| Current Consumption | 0.9 A maximum | At rated Pout |
HD35099 control and monitoring
| Pin | Function | Description |
|---|---|---|
| 1 | VDD | +30 VDC |
| 2 | GND | Ground |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +75 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95% | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 80 × 50 × 16.8 mm | Without connectors |
| RF Connectors In/Out | SMA female | |
| DC Power | Feed Thru |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD35099 documentation
Download HD35099 V1.2.pdf for the complete specifications, test conditions, drawings and available options.
About HD35099
HD35099 is listed for 1,000–6,000 MHz operation.
Output: 3 W minimum Psat. Gain: 35 dB minimum. P1dB: 2 W typical. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 28 – 30 VDC. Confirm cooling and installation requirements in the datasheet.
See the model-specific interface table above. Optional functions must be confirmed for the ordered unit.
Dimensions: 80 × 50 × 16.8 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.