HD35114 RF Amplifier
Module
HD35114
| FREQUENCY RANGE500–2,000 MHz | OUTPUT POWER30 dBm (catalog) |
| GAIN41 dB minimum | SUPPLY VOLTAGE15 V (catalog) |
| CONFIGURATIONModule | CATEGORYLow Frequency Module |
HD35114 electrical specifications
Source: HD35114 V0.1.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 0.5 – 2.0 GHz | |
| Power Output @ P1 dB | 30 dBm (1 W) minimum | CW |
| Power Gain | 41 dB minimum | 42 dB typical |
| Input Return Loss | 10 dB typical | |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 20 dBm/Tone, A = 1 MHz |
| Harmonics | -20 dBc typical | At rated Pout |
| Noise Figure | 3 dB maximum | |
| Spurious | -60 dBc maximum | Non-harmonics |
| Current Consumption | 0.9 A maximum | At rated Pout, 0.8A typical |
HD35114 control and monitoring
| Pin | Function | Description |
|---|---|---|
| 2 | GND | GND |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -40 to +60 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95 % | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 62.48 × 43.18 × 54.1 mm | Excluding connectors |
| RF Connectors In/Out | SMA female | |
| DC Power | Feed Thru | |
| Cooling | External heatsink | Forced air required |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD35114 documentation
Download HD35114 V0.1.pdf for the complete specifications, test conditions, drawings and available options.
About HD35114
HD35114 is listed for 500–2,000 MHz operation.
Output: 30 dBm (catalog). Gain: 41 dB minimum. P1dB: 30 dBm (1 W) minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 15 V (catalog). Cooling: External heatsink.
See the model-specific interface table above. Optional functions must be confirmed for the ordered unit.
Dimensions: 62.48 × 43.18 × 54.1 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.