HD35131 RF Amplifier
System
HD35131
| FREQUENCY RANGE700–3,000 MHz | OUTPUT POWER125 W minimum Psat |
| GAIN51 dB minimum | SUPPLY VOLTAGE100 – 240 VAC |
| CONFIGURATIONSystem | CATEGORYLow Frequency Amplifier System |
HD35131 electrical specifications
Source: HD35131 (0.7 – 3GHz, 125W, 51dB) V0.2.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 0.7 – 3.0 GHz | |
| Power Output @ Psat | 125 W minimum | CW or Pulse |
| Power Gain | 51 dB minimum | |
| Power Gain Flatness | 3 dB p-p maximum | Constant input power |
| Input / Output Return Loss | -10 dB maximum | Relative to 50 Ohm |
| Harmonics | -20 dBc typical | At rated output power |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 100 – 240 VAC | |
| Power Consumption | 1000 W maximum | At rated output |
HD35131 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Interface Connector | 9-Pin D-Sub | Rear panel |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Ambient Temperature | 0 to +50 °C | |
| Relative Humidity | up to 95 % | Non Condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| RF Conn. In / Out / Sample | N-Female | Front or rear panel |
| Interface Connector | 9-Pin D-Sub | Rear panel |
| Cooling | Built-in fan cooling | Variable speed |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD35131 documentation
Download HD35131 (0.7 – 3GHz, 125W, 51dB) V0.2.pdf for the complete specifications, test conditions, drawings and available options.
About HD35131
HD35131 is listed for 700–3,000 MHz operation.
Output: 125 W minimum Psat. Gain: 51 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 100 – 240 VAC. Cooling: Built-in fan cooling.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.