HD35132 RF Amplifier
System
HD35132
| FREQUENCY RANGE1,000–6,000 MHz | OUTPUT POWER1000 W minimum Psat |
| GAIN60 dB minimum | SUPPLY VOLTAGE120/208, 3-Ph, 47 – 63 Hz |
| CONFIGURATIONSystem | CATEGORYBroadband Amplifier System |
HD35132 electrical specifications
Source: HD35132 (1 – 6GHz, 1000W, 60dB) V0.5.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 1.0 – 6.0 GHz | CW or Pulse |
| Power Output @ Psat | 1000 W minimum | 1200 W typical |
| Power @ P1 dB | 600 W minimum | 700 W typical |
| Power Gain | 60 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 4 dB p-p maximum | At rated input power |
| Gain Adjustment Range | 20 dB minimum | Local or remote |
| Input / Output Return Loss | -10 dB maximum | |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 50 dBm/Tone, A = 1 MHz |
| Harmonics | -20 dBc typical | At rated output |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 120/208, 3-Ph, 47 – 63 Hz | Opt: 230/400 VAC, 3-Ph |
| Power Consumption | 15 kW maximum | At rated output |
HD35132 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Interface Connector | 9-Pin D-Sub | Rear panel |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Ambient Temperature | 0 to +50 °C | |
| Relative Humidity | up to 95 % | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions W x H x D | 27U standard rack height | Alternate height TBQ |
| Interface Connector | 9-Pin D-Sub | Rear panel |
| AC Power | MS Style | Or equivalent |
| Cooling: Built in Quiet-Cool | Closed-circuit air-liquid cooling |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD35132 documentation
Download HD35132 (1 – 6GHz, 1000W, 60dB) V0.5.pdf for the complete specifications, test conditions, drawings and available options.
About HD35132
HD35132 is listed for 1,000–6,000 MHz operation.
Output: 1000 W minimum Psat. Gain: 60 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 120/208, 3-Ph, 47 – 63 Hz. Cooling: Closed-circuit air-liquid cooling.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Dimensions: 27U standard rack height. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.