HD35197 RF Amplifier
System
HD35197
| FREQUENCY RANGE1–3,000 MHz | OUTPUT POWER100 W minimum | 50 W minimum Psat |
| GAIN50 dB minimum | 47 dB minimum | SUPPLY VOLTAGE100 – 240 VAC |
| CONFIGURATIONSystem | CATEGORYLow Frequency Amplifier System |
HD35197 electrical specifications
Source: HD35197 (1 – 3000MHz, 100,50W, 50,47dB) V0.3.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Band | A | B | Band switching @ 15 mS typical |
| Operating Frequency Range | 1- 1000 MHz | 1.0 – 3.0 GHz | |
| Power Output @ Psat | 100 W minimum | 50 W minimum | CW |
| Power Gain | 50 dB minimum | 47 dB minimum | 0 dBm or less for rated Pout |
| Gain Adjustment Range | 20 dB minimum | Local or remote |
| Input Return Loss | -10 dB maximum | |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 37 dBm/Tone, A = 1 MHz |
| Harmonics | -20 dBc typical | At rated Pout |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 100 – 240 VAC | 47-63 Hz |
| Power Consumption | 1000 W maximum | At rated Pout |
HD35197 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| AC Power / Interface Connector | IEC 60320-C14 / 9-Pin D-Sub | Or equivalent |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95% | Non Condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions W x H x D | 483 × 177 × 560 mm | 4U, excluding handles |
| AC Power / Interface Connector | IEC 60320-C14 / 9-Pin D-Sub | Or equivalent |
| Air-Cooling | Built-in fan cooling | Variable speed |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD35197 documentation
Download HD35197 (1 – 3000MHz, 100,50W, 50,47dB) V0.3.pdf for the complete specifications, test conditions, drawings and available options.
About HD35197
HD35197 is listed for 1–3,000 MHz operation.
Output: 100 W minimum | 50 W minimum Psat. Gain: 50 dB minimum | 47 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 100 – 240 VAC. Cooling: Built-in fan cooling.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Dimensions: 483 × 177 × 560 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.