HD35210 RF Amplifier
Module
HD35210
| FREQUENCY RANGE6,000–12,000 MHz | OUTPUT POWER100 Pulse (catalog) |
| GAIN50 dB minimum | SUPPLY VOLTAGE32 VDC Nom |
| CONFIGURATIONModule | CATEGORYPulse Amplifier Module |
HD35210 electrical specifications
Source: HD35210 V1.2.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 6.0 – 12.0 GHz | |
| Power Output @ Pulse | 100 W minimum / 120 W typical | Peak pulse |
| Power Gain | 50 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 3.0 dB p-p maximum | Constant input power |
| Input Return Loss | -10 dB maximum | |
| Harmonics | -25 dBc typical | At rated Pout |
| Noise Figure | 10 dB maximum | |
| Operating Voltage | 32 VDC Nom |
HD35210 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| RF Connectors In/Out | SMA Female / Type-N Female | |
| DC Power / Interface Connector | 7-Pin Hybrid D-Sub | 7W2 |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +75 °C | |
| Relative Humidity | up to 95% | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 180 × 200 × 27 mm | Excluding connectors |
| RF Connectors In/Out | SMA Female / Type-N Female | |
| DC Power / Interface Connector | 7-Pin Hybrid D-Sub | 7W2 |
| Cooling | External heatsink | Forced air required |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD35210 documentation
Download HD35210 V1.2.pdf for the complete specifications, test conditions, drawings and available options.
About HD35210
HD35210 is listed for 6,000–12,000 MHz operation.
Output: 100 Pulse (catalog). Gain: 50 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 32 VDC Nom. Cooling: External heatsink.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Dimensions: 180 × 200 × 27 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.