HD35213 RF Amplifier
Module
HD35213
| FREQUENCY RANGE2,000–3,000 MHz | OUTPUT POWER200 W minimum Psat |
| GAIN53 dB minimum | SUPPLY VOLTAGE28 VDC Nom |
| CONFIGURATIONModule | CATEGORYLow Frequency Module |
HD35213 electrical specifications
Source: HD35213 V1.1.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 2.0 – 3.0 GHz | |
| Power Output @ Psat | 200 W minimum | CW |
| Power Gain | 53 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 3.0 dB p-p maximum | Constant input power |
| Input Return Loss | -10 dB maximum | Relative to 50 Ohm |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 43 dBm/Tone, A = 1 MHz |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 28 VDC Nom | |
| Current Consumption | 35 A typical | At rated Pout |
HD35213 control and monitoring
| Pin | Function | Description |
|---|---|---|
| 1 | N/c | N/c |
| 2 | N/c | N/c |
| 5 | SHUTDOWN | Enable = TTL High or Open; Disable = TTL Low or Short |
| Al,A2 | VDD | 28 VDC |
| A3,A4 | GND | Ground |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +75 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95% | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 270 × 200 × 27 mm | Excluding connectors |
| RF Connectors In/Out | SMA female / Type-N female |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD35213 documentation
Download HD35213 V1.1.pdf for the complete specifications, test conditions, drawings and available options.
About HD35213
HD35213 is listed for 2,000–3,000 MHz operation.
Output: 200 W minimum Psat. Gain: 53 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 28 VDC Nom. Confirm cooling and installation requirements in the datasheet.
See the model-specific interface table above. Optional functions must be confirmed for the ordered unit.
Dimensions: 270 × 200 × 27 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.