HD35214 RF Amplifier
Module
HD35214
| FREQUENCY RANGE6,000–7,000 MHz | OUTPUT POWER200 W minimum Psat |
| GAIN53 dB minimum | SUPPLY VOLTAGE28 VDC Nom |
| CONFIGURATIONModule | CATEGORYBroadband Amplifier Module |
HD35214 electrical specifications
Source: HD35214 V0.1.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 6.0 – 7.0 GHz | |
| Power Output @ Psat | 200 W minimum | CW |
| Power Gain | 53 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 3.0 dB p-p maximum | Constant input power |
| Input / Output Return Loss | 10 dB minimum | |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 43 dBm/Tone, A = 1 MHz |
| Harmonics | -30 dBc typical | At rated Pout |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 28 VDC Nom | |
| Current Consumption | 35 A maximum | At rated Pout |
| maximum Input Power | +8 dBm maximum | <10 Sec without damage |
HD35214 control and monitoring
| Pin | Function | Description |
|---|---|---|
| 1 | FWD | OPTION 101 – Forward power detect |
| 2 | VVA | OPTION 103 – Variable Voltage Attenuator |
| Al,A2 | VDD | 28 VDC |
| A3,A4 | GND | Ground |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +75 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95% | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 270 × 200 × 27 mm | Excluding connectors |
| RF Connectors In/Out | SMA | Type-N female | |
| Cooling | External heatsink | Forced air required |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD35214 documentation
Download HD35214 V0.1.pdf for the complete specifications, test conditions, drawings and available options.
About HD35214
HD35214 is listed for 6,000–7,000 MHz operation.
Output: 200 W minimum Psat. Gain: 53 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 28 VDC Nom. Cooling: External heatsink.
See the model-specific interface table above. Optional functions must be confirmed for the ordered unit.
Dimensions: 270 × 200 × 27 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.