HD35218 RF Amplifier
System
HD35218
| FREQUENCY RANGE2,700–2,900 MHz | OUTPUT POWER8,000 W (catalog) |
| GAIN69 dB (catalog) | SUPPLY VOLTAGE200–240 V (catalog) |
| CONFIGURATIONSystem | CATEGORYLow Frequency Amplifier System |
HD35218 electrical specifications
Source: HD35218 (2.7 – 2.9GHz, 8000W) V0.3.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 2.7 – 2.9 GHz | |
| Peak Output Power | 8 KWatt minimum | |
| Rise / Fall Time | <50 ns typical / 60 nS maximum | 10% to 90% |
| Harmonics | -20 dBc maximum | |
| Spurious | -50 dBc maximum | |
| Power flatness | S1.0 dB | Over operating frequency |
| Pulse Width Variation (Jitter) | <-70 ns |
HD35218 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| RF Connectors In/Out | Type N-F / Waveguide WR284 | Front/Rear Panel Standard |
| Interface Connector | TBD |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Ambient Temperature | -20 to +55°C | |
| Storage Temperature | -40 to +70°C | |
| Relative Humidity | 95% @ 40°C | Non-condensing |
| EMI/EMC | MIL STD 461E |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions W x H x D | 13U standard rack height | Alternate height TBQ |
| RF Connectors In/Out | Type N-F / Waveguide WR284 | Front/Rear Panel Standard |
| RF Output Monitoring FWD / REV | Type N-F | |
| AC Power | 380/220 VAC, 48-64Hz, 3 Phase & Natural | 4 Wires |
| Interface Connector | TBD | |
| Cooling | Built-in forced-air cooling |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD35218 documentation
Download HD35218 (2.7 – 2.9GHz, 8000W) V0.3.pdf for the complete specifications, test conditions, drawings and available options.
About HD35218
HD35218 is listed for 2,700–2,900 MHz operation.
Output: 8,000 W (catalog). Gain: 69 dB (catalog). Preserve the rating definitions and conditions in the complete datasheet.
Supply: 200–240 V (catalog). Cooling: Built-in forced-air cooling.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Dimensions: 13U standard rack height. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.