HD35239 RF Amplifier
System
HD35239
| FREQUENCY RANGE40,000–50,000 MHz | OUTPUT POWER30 Typ (catalog) |
| GAIN45 dB minimum | SUPPLY VOLTAGE120/208 VAC, 3-Ph, 47 – 63 Hz |
| CONFIGURATIONSystem | CATEGORYMillimeter Amplifier System |
HD35239 electrical specifications
Source: HD35239 (40 – 50GHz, 20W, 45dB) V0.5.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 40.0 – 50.0 GHz | |
| Power Gain | 45 dB minimum | 0 dBm or less for rated Pout |
| Power Gain Flatness | 5 dB p-p typical | Constant input power |
| Gain Adjustment Range | 20 dB minimum | Local or remote capable |
| Input / Return Loss | -10 dB maximum | |
| 2-Tone Intermodulation (IMD) | -30 dBc typical | 35 dBm/Tone, A = 1 MHz |
| Harmonics | -20 dBc typical | At rated output power |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 120/208 VAC, 3-Ph, 47 – 63 Hz | Opt: 230/400 VAC, 3-Ph |
| Power Consumption | 5000 W maximum | At rated output |
HD35239 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Interface Connector | 9-Pin D-Sub | Rear panel |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | up to 95 % | Non-condensing |
| Altitude | 3000 meters |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions W x H x D | 421 × 442 × 800 mm | 10U, excluding handles |
| Interface Connector | 9-Pin D-Sub | Rear panel |
| AC Power | MS Connector | Or equivalent |
| Cooling | Built-in fan cooling | Variable speed |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD35239 documentation
Download HD35239 (40 – 50GHz, 20W, 45dB) V0.5.pdf for the complete specifications, test conditions, drawings and available options.
About HD35239
HD35239 is listed for 40,000–50,000 MHz operation.
Output: 30 Typ (catalog). Gain: 45 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 120/208 VAC, 3-Ph, 47 – 63 Hz. Cooling: Built-in fan cooling.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Dimensions: 421 × 442 × 800 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.