HD35271 RF Amplifier
Module
Product photograph pending confirmation.
HD35271
| FREQUENCY RANGE6,000–18,000 MHz | OUTPUT POWER10 dBm (catalog) |
| GAIN17 dB minimum | SUPPLY VOLTAGE15 VDC Nom |
| CONFIGURATIONModule | CATEGORYLow Noise Amplifier Module |
HD35271 electrical specifications
Source: HD35271 V0.1.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 6 – 18 GHz | |
| Power Output | 10 dBm minimum | CW |
| Power Gain | 17 dB minimum | 19 dB typical |
| Gain Flatness | +2.0 dB maximum | |
| Input Return Loss | 10 dB minimum | Relative to 50 Ohm |
| Noise Figure | 1.9 dB maximum | 1.7 dB typical |
| Spurious | -60 dBc maximum | Non-harmonics |
| Operating Voltage | 15 VDC Nom | |
| Current Consumption | 200 mA typical |
HD35271 control and monitoring
| Pin | Function | Description |
|---|---|---|
| 2 | GND | Ground |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -20 to +75 °C | |
| Storage Temperature | -40 to +85 °C | |
| Relative Humidity | 5to 95% | Non-condensing |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Dimensions | 18.3 × 19.1 × 7.7 mm | |
| RF Connectors In/Out | SMA (F) | |
| DC Power / Interface Connector | Feed-Thru | |
| Ground | Solder Lug |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD35271 documentation
Download HD35271 V0.1.pdf for the complete specifications, test conditions, drawings and available options.
About HD35271
HD35271 is listed for 6,000–18,000 MHz operation.
Output: 10 dBm (catalog). Gain: 17 dB minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 15 VDC Nom. Confirm cooling and installation requirements in the datasheet.
See the model-specific interface table above. Optional functions must be confirmed for the ordered unit.
Dimensions: 18.3 × 19.1 × 7.7 mm. Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.