HD35278 RF Amplifier
Module
HD35278
| FREQUENCY RANGE6,000–18,000 MHz | OUTPUT POWER27 W (catalog) |
| GAIN23 dB minimum / 30 dB maximum | SUPPLY VOLTAGE15 V (catalog) |
| CONFIGURATIONModule | CATEGORYLow Noise Amplifier Module |
HD35278 electrical specifications
Source: HD35278 V0.1.pdf. Refer to the complete datasheet for all test conditions, optional ratings and protection limits.
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Frequency Range | 6.0 – 18.0 GHz | |
| Power Output @ P1 dB | 27 dBm minimum | |
| Linear Gain | 23 dB minimum / 30 dB maximum | |
| Small Signal Gain Flatness | +1.5 dB maximum | Over Temp & Freq |
| Noise Figure | 6 dB maximum | |
| 3rd Order Intercept Point | +36 dBm minimum | |
| Harmonics | -20 dBc typical | |
| Spurious | -60 dBc maximum | Non-harmonics |
| VSWR Input / Output | 2:1Max | |
| DC Consumption | 0.8 A typical |
HD35278 control and monitoring
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Connectors (RF Ports) | SMA-F | MIL-39012 or equivalent |
Confirm connector orientation and optional functions against the complete model-specific documentation before wiring.
Operating and storage conditions
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Operating Case Temperature | -40 to +85 °C | |
| Storage Temperature | -55 to +125 °C | Non-operating |
| Relative Humidity | 95% | Non-condensing |
| Reliability | MIL-STD-883 | Designed to meet |
Mechanical specifications and cooling
| Parameter | Specification | Conditions / notes |
|---|---|---|
| Connectors (RF Ports) | SMA-F | MIL-39012 or equivalent |
Use the original outline drawing for mounting-hole positions, connector clearances and ordered options.
HD35278 documentation
Download HD35278 V0.1.pdf for the complete specifications, test conditions, drawings and available options.
About HD35278
HD35278 is listed for 6,000–18,000 MHz operation.
Output: 27 W (catalog). Gain: 23 dB minimum / 30 dB maximum. P1dB: 27 dBm minimum. Preserve the rating definitions and conditions in the complete datasheet.
Supply: 15 V (catalog). Confirm cooling and installation requirements in the datasheet.
Review the matching datasheet and confirm the required interface and monitoring options when requesting a quote.
Review the mechanical table and original outline drawing before planning mounting and connector clearances.
Protection ratings are subject to the datasheet conditions and time limits. They do not imply unlimited operation under overload or mismatch.